Why is Cold Air Coming Out of My Vents when the Heat is On in Aliante, NV? Clogged Condensate Line & More?

The last thing you want to feel when the furnace is on, and air is blowing would be cold air coming out of the vents. During these winter months, we still need to have our heat on most days to stay warm. Cold air blowing out of the vents is a problem that you want to get fixed as soon as possible. If you know a few things you can check, sometimes, you can fix the problem without calling in the pros. Air Supply Heating & Air Conditioning is here to share some tips to help you troubleshoot your furnace when you aren’t getting the heat that you want from it.

Check Thermostat Settings

The very first thing that you want to check when you have this problem is the thermostat. More often than you would think, there is a setting that isn’t quite right. You need to make sure the heat is in fact on, and the temperature is set where you would feel most comfortable. You can also make sure the fan isn’t turned on. If it is, you will have air blowing from the vents around the clock, even when the furnace isn’t actively heating the air. Switch that fan to off and see if the problem is solved.

Inspect AC Condensate Line

Hopefully, you have a high efficiency furnace in your home. If you do, there is always a byproduct while they are functioning. This condensed liquid is usually nothing you need to worry about because it drains away. Sometimes, there is a clog in the condensate drain line and it can cause cold air to come out of the vents as well as leak some water.

Is Furnace Pilot Light Out?

There is a pilot light in every furnace, and if yours isn’t lit, you aren’t going to get warm air coming from your vents. The pilot light may simply be out, or it isn’t getting lit properly. Sometimes, this is caused by a blockage of soot and dirt, or the thermocouple may be malfunctioning.

Is Gas Supply Sufficient

If you have a furnace that uses natural gas to operate, it is going to need plenty of it to get the job done. Make sure the gas supply hasn’t been turned off for one reason or another. You should also check to make sure the gas valve wasn’t closed. When both of those options check out, you may have a blocked line that is interrupting the flow of gas.

Forced Air Furnace, Heat Pump & Boiler Heating Diagnosis, Repair, Replacement & More in Summerlin, North LV, Henderson, Centennial, Enterprise, Lone Mountain Village, Paradise, Sunrise Manor, Spring Valley, Aliante, Desert Shores, Eldorado, Peccole Ranch, Silverado Ranch, Tuscany Village, Whitney, Winchester & Las Vegas Nevada

If you have cold air coming from your vents when the furnace is supposed to be on, and nothing you do helps, you can turn to the professionals at Air Supply Heating & Air Conditioning to get to the bottom of whatever is causing your problem. Our highly qualified technicians will get your furnace back up and running in no time. Call us today!